End nozzles should be matched to the intermediate nozzles for uniform coverage. The rated flow of end nozzles is double that of the intermediate nozzles:
|
End Nozzle Model Number |
Rated Flow |
Former Imperial |
GPM at 12 psi |
|
ES4 |
9.0 |
ES1 |
2.0 |
|
ES9 |
18.0 |
ES2 |
4.0 |
|
EA13 |
27.0 |
EA3 |
6.0 |
|
EA18 |
36.2 |
EA4 |
8.0 |
|
EB27 |
54.4 |
EB6 |
12.0 |
PRESSURE AT THE SPRAY BAR:
To give the designed rate of discharge, the pressure required at the nozzle orifice is approximately 80 kPa (0.83 Bar; 12 psi).
This pressure may be adjusted slightly to vary the discharge rate of the nozzles.
However the pressure at the nozzle orifice must never be less than 70 kPa (0.7 Bar; 10 psi). Below this pressure, the fan pattern and liquid distribution of the nozzle will not be correct.